The published performance values are reference information, not batch test results or finished-assembly ratings. Confirm the material grade, test method and acceptance limits for your order. For flame performance, request the applicable test classification and supporting documentation; do not infer a rating from this table alone.
PTFE Capillary Tubing AWG Size Chart
AWG 30 through AWG 0 PTFE capillary tubing is available in S, T and L wall options. Custom ID, OD, tolerances, lengths and non-standard miniature tubing can be produced to customer drawings.
| AWG Size | ID (mm) | OD (mm) | Wall Thickness (mm) | Roll Length (m) | ||||||
|---|---|---|---|---|---|---|---|---|---|---|
| S | T | L | S | T | L | S | T | L | ||
| 30 | 0.30±0.05 | 0.76±0.05 | 0.76±0.05 | 0.6±0.05 | 0.23±0.05 | 0.23±0.05 | 0.15±0.04 | 305 | 305 | 305 |
| 28 | 0.38±0.05 | 0.84±0.05 | 0.84±0.05 | 0.68±0.05 | 0.23±0.05 | 0.23±0.05 | 0.15±0.04 | 305 | 305 | 305 |
| 26 | 0.46±0.05 | 0.92±0.05 | 0.92±0.05 | 0.76±0.05 | 0.23±0.05 | 0.23±0.05 | 0.15±0.04 | 305 | 305 | 305 |
| 24 | 0.56±0.05 | 1.16±0.05 | 1.06±0.05 | 0.86±0.05 | 0.30±0.06 | 0.25±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 23 | 0.66±0.05 | 1.26±0.05 | 1.16±0.05 | 0.96±0.05 | 0.30±0.06 | 0.25±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 22 | 0.71±0.05 | 1.31±0.05 | 1.21±0.05 | 1.01±0.05 | 0.30±0.06 | 0.25±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 21 | 0.81±0.05 | 1.41±0.05 | 1.31±0.05 | 1.11±0.05 | 0.30±0.06 | 0.25±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 20 | 0.86±0.05 | 1.66±0.05 | 1.46±0.05 | 1.16±0.05 | 0.40±0.07 | 0.30±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 19 | 0.96±0.05 | 1.76±0.05 | 1.56±0.05 | 1.26±0.05 | 0.40±0.07 | 0.30±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 18 | 1.07±0.05 | 1.87±0.05 | 1.67±0.05 | 1.37±0.05 | 0.40±0.07 | 0.30±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 17 | 1.19±0.05 | 1.99±0.05 | 1.79±0.05 | 1.49±0.05 | 0.40±0.07 | 0.30±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 16 | 1.34±0.05 | 2.14±0.05 | 1.94±0.05 | 1.64±0.05 | 0.40±0.07 | 0.30±0.06 | 0.15±0.04 | 305 | 305 | 305 |
| 15 | 1.50±0.05 | 2.30±0.05 | 2.10±0.05 | 1.8±0.05 | 0.40±0.07 | 0.30±0.06 | 0.15±0.04 | 153 | 153 | 153 |
| 14 | 1.68±0.08 | 2.48±0.08 | 2.28±0.08 | 2.08±0.08 | 0.40±0.07 | 0.30±0.06 | 0.20±0.05 | 153 | 153 | 153 |
| 13 | 1.93±0.08 | 2.73±0.08 | 2.53±0.08 | 2.33±0.08 | 0.40±0.07 | 0.30±0.06 | 0.20±0.05 | 153 | 153 | 153 |
| 12 | 2.16±0.08 | 2.96±0.08 | 2.76±0.08 | 2.56±0.08 | 0.40±0.07 | 0.30±0.06 | 0.20±0.05 | 153 | 153 | 153 |
| 11 | 2.41±0.08 | 3.21±0.08 | 3.01±0.08 | 2.81±0.08 | 0.40±0.07 | 0.30±0.06 | 0.20±0.05 | 153 | 153 | 153 |
| 10 | 2.69±0.08 | 3.49±0.08 | 3.29±0.08 | 3.09±0.08 | 0.40±0.07 | 0.30±0.06 | 0.20±0.05 | 153 | 153 | 153 |
| 9 | 3.00±0.08 | 4.00±0.08 | 3.76±0.08 | 3.4±0.08 | 0.50±0.07 | 0.38±0.07 | 0.20±0.05 | 100 | 100 | 100 |
| 8 | 3.38±0.08 | 4.38±0.08 | 4.14±0.08 | 3.78±0.08 | 0.50±0.07 | 0.38±0.07 | 0.20±0.05 | 100 | 100 | 100 |
| 7 | 3.76±0.08 | 4.76±0.08 | 4.52±0.08 | 4.16±0.08 | 0.50±0.07 | 0.38±0.07 | 0.20±0.05 | 100 | 100 | 100 |
| 6 | 4.22±0.08 | 5.22±0.08 | 4.98±0.08 | 4.72±0.08 | 0.50±0.07 | 0.38±0.07 | 0.25±0.06 | 100 | 100 | 100 |
| 5 | 4.72±0.10 | 5.72±0.1 | 5.48±0.1 | 5.22±0.1 | 0.50±0.07 | 0.38±0.07 | 0.25±0.06 | 100 | 100 | 100 |
| 4 | 5.28±0.10 | 6.28±0.1 | 6.04±0.1 | 5.78±0.1 | 0.50±0.07 | 0.38±0.07 | 0.25±0.06 | 100 | 100 | 100 |
| 3 | 5.94±0.10 | 6.94±0.1 | 6.70±0.1 | 6.44±0.1 | 0.50±0.07 | 0.38±0.07 | 0.25±0.06 | 100 | 100 | 100 |
| 2 | 6.68±0.10 | 7.68±0.1 | 7.44±0.1 | 7.18±0.1 | 0.50±0.07 | 0.38±0.07 | 0.25±0.06 | 100 | 100 | 100 |
| 1 | 7.46±0.10 | 8.46±0.1 | 8.22±0.1 | 7.96±0.1 | 0.50±0.07 | 0.38±0.07 | 0.25±0.06 | 100 | 100 | 100 |
| 0 | 8.38±0.10 | 9.38±0.1 | 9.14±0.1 | 8.88±0.1 | 0.50±0.07 | 0.38±0.07 | 0.25±0.06 | 100 | 100 | 100 |
S, T and L identify the available wall series shown in the table. Contact us when your project requires a different tolerance, wall thickness or coil length.
Precision PTFE Capillary Tubing by Custom ID and OD
Specify inner diameter, outer diameter, tolerance, wall thickness, length and fluid conditions for custom PTFE capillary tubing or micro tube. Sample availability, cost and shipping conditions are confirmed during RFQ review.
For a faster quotation: send dimensions or a drawing, material or filled grade, tolerance, quantity, application conditions and delivery country.
Custom PTFE Capillary Tubing RFQ Checklist
Send the required bore, outside diameter and application details so we can review extrusion feasibility and tolerance.
Size system: AWG, metric or imperial ID and OD with required wall thickness
Precision details: tolerance, concentricity, straight length or coil length and cut-length requirement
Application: chromatography, analytical instruments, precision fluid transfer, insulation or another stated use
Order support: samples and small-batch orders are supported; sample availability and production timing are confirmed after technical and commercial review
REAL FACTORY PRODUCTION
PTFE Capillary Tubing Production
Controlled workshop production and operator inspection for small-ID PTFE capillary tubing.