PTFE tubing does not have one universal pressure rating. The allowable working pressure depends on the tube’s inside diameter (ID), outside diameter (OD), wall thickness, PTFE grade, manufacturing method, operating temperature, pressure cycle, chemical medium, unsupported length and connection method. A pressure value copied from another tube size should therefore not be used for a custom order.
This guide explains how engineers and buyers can evaluate these factors before requesting custom PTFE extruded tubing.
Why PTFE Tubing Has No Single Pressure Rating
Two tubes made from PTFE may behave very differently even when their outside diameters look similar. A small change in ID changes the wall thickness, and a change in wall thickness changes how the tube responds to internal pressure. Temperature also affects stiffness and deformation. Connections can become the limiting point even when the tube wall itself is adequate.
Published pressure figures should be treated as size- and condition-specific data. Final suitability must be reviewed for the exact tube construction and operating environment.
| Selection factor | Why it matters | Information to provide |
|---|---|---|
| ID and OD | They determine the wall thickness and flow passage. | Nominal ID, OD and required tolerances |
| Operating temperature | PTFE becomes more flexible as temperature rises, reducing the available pressure margin. | Normal and maximum temperature |
| Pressure condition | Steady pressure, vacuum, pulsation and pressure spikes create different loads. | Normal pressure, peak pressure and cycle frequency |
| Chemical medium | PTFE resists many chemicals, but the complete assembly and fittings must also be compatible. | Fluid name, concentration and temperature |
| Length and routing | Long unsupported runs, tight bends and vibration increase deformation risk. | Cut length or coil length, bend radius and supports |
| Connections | Compression fittings, barbs, flares and custom ends may govern system performance. | Fitting type, material and assembly method |
How ID, OD and Wall Thickness Work Together
The nominal wall thickness of a round tube is calculated as follows. This geometric relation is not a working-pressure calculation. Working pressure is the approved service limit for specified conditions; proof or test pressure applies to a defined verification procedure, while burst pressure describes failure in a specified test. They are not interchangeable. Obtain tube- and assembly-specific evidence at the stated temperature and duty:
For the same OD, a smaller ID creates a thicker wall. For the same wall thickness, a larger tube generally requires more careful pressure evaluation because the internal force acts over a larger diameter. Dimensional tolerances also matter: pressure assessment should consider the minimum wall condition, not only the nominal dimensions.
Customers often provide only an OD. For a useful manufacturing review, Pengrowth needs both ID and OD, or one diameter plus the required wall thickness. If flow is critical, identify which diameter is the functional dimension and where the tighter tolerance is required.
Why Operating Temperature Requires Pressure Derating
PTFE is selected for a wide service-temperature range, but temperature resistance and pressure resistance are not the same specification. A tube may tolerate the temperature chemically while becoming more flexible mechanically. As temperature increases, creep and dimensional change become more important, especially during long-duration loading.
For elevated-temperature service, provide the continuous temperature, short-duration maximum temperature, exposure time and whether pressure is applied during heating and cooling. The tube, fitting and support system should be evaluated together.
Static Pressure, Pulsation, Vacuum and Pressure Peaks
A continuous, stable pressure is different from a rapidly cycling load. Pumps, valves and equipment start-up can create pressure peaks above the normal gauge reading. Repeated cycling can also move the tube at the fitting or bend.
Steady pressure
Confirm continuous pressure, duration and temperature. Long-term creep may control the design.
Pressure pulsation
Provide cycle frequency and peak pressure. Routing and connection stability become more important.
Vacuum service
Wall collapse and ovalization must be considered, particularly with larger diameters or high temperature.
Pressure spikes
State the maximum possible transient pressure rather than only the normal operating value.
Tube Type Also Changes the Selection
Flexible or semi-rigid extruded tubing is commonly used for chemical transfer, insulation and equipment connections. It is selected by ID, OD, wall thickness, tolerance and routing requirements.
PTFE capillary tubing focuses on small ID, precision flow and dimensional control. See the PTFE capillary tubing page when the bore is very small or analytical fluid handling is involved.
PTFE corrugated hose provides greater routing flexibility, while a stainless steel braided PTFE hose adds external reinforcement. A braid does not remove the need to confirm liner dimensions, fittings, temperature and pressure.
Fittings, Bend Radius and Installation
A tubing system can fail at the connection before the straight tube wall reaches its limit. Check fitting geometry, insertion depth, ferrule or flare design, surface condition and assembly method. Avoid sharp edges that can cut the tube.
Tight bending can flatten the bore and thin the outside of the bend. Use a practical bend radius, support long runs, and prevent rubbing against moving or abrasive surfaces. Where repeated movement is expected, specify the motion range and cycle frequency during the quotation stage.
A Practical PTFE Tubing Selection Workflow
- Define the medium, concentration and possible cleaning fluids.
- Confirm continuous and maximum operating temperatures.
- Record normal pressure, peak pressure, vacuum and pulsation.
- Specify ID, OD, wall thickness, tolerance and required length.
- Identify flexible, semi-rigid, corrugated or braided construction.
- Provide fitting details, bend radius, supports and movement conditions.
- Review a prototype or sample before production when the application is critical.
Information Needed for a Fast Custom Quote
- ID, OD and wall thickness
- Dimensional tolerances and critical measurement points
- Straight cut length or coil length
- Normal pressure, peak pressure and vacuum level
- Continuous and maximum temperature
- Chemical medium and concentration
- Quantity, color and material grade if specified
- Fitting, bend, support and movement requirements
- Drawing or sample when available
How Pengrowth Supports Custom PTFE Tubing Projects
Sample and production lead times are confirmed after reviewing material, dimensions, process, quantity and inspection requirements.
Agree the inspection and document scope for the specific tube order, including material identification, controlling dimensions, sampling, acceptance and shipment records. Confirm which checks and reports are included in the quotation. For more information about chemical-transfer selection, read How to Choose PTFE Tubing for Chemical Transfer Applications.
Frequently Asked Questions
Can PTFE tubing be used for high-pressure service?
PTFE tubing may be used in pressure applications when its dimensions, temperature, construction, fittings and safety requirements are suitable. Do not select it from material temperature resistance alone. Submit the complete operating conditions for review.
Does a thicker PTFE tube wall always mean a higher pressure rating?
A thicker wall generally improves pressure resistance, but diameter, temperature, PTFE grade, extrusion quality, fittings, routing and pressure cycling still affect the result.
What pressure value should be used for a custom PTFE tube?
Use a value confirmed for the exact ID, OD, wall thickness, temperature and assembly. A rating from a different size or fitting system should not be transferred directly.
Is stainless steel braided PTFE hose the same as extruded PTFE tubing?
No. A braided hose combines a PTFE liner with external reinforcement and usually uses hose fittings. Plain extruded tubing has a different construction and should be evaluated separately.
Can Pengrowth make a sample before production?
Sample availability, cost and shipping conditions are confirmed during RFQ review.
Request a PTFE Tubing Review
Send your ID, OD, wall thickness, medium, temperature, working pressure, peak pressure, length, quantity and fitting requirements. Pengrowth will review manufacturability and recommend a suitable tubing construction for quotation.